À̽½Á¡(Dew Point) ¿Âµµ, Magnus formula

ÀÛ¼ºÀÚ Uploader : rainman ÀÛ¼ºÀÏ Upload Date: 2021-02-15º¯°æÀÏ Update Date: 2021-02-15Á¶È¸¼ö View : 7551

À̽½Á¡ ¿Âµµ Tdp (¡É) ¸¦ ±¸ÇÏ´Â ½ÄÀ¸·Î Àß ¾Ë·ÁÁø °ø½ÄÀÌ´Ù.

Tdp = c*(ln(RH/100)+b*T/(c+T)) / (b-ln(RH/100)+b*T/(c+T))

RH : »ó´ë½Àµµ, Relative Humidity (%)
T : ±â¿Â (¡É)

ÀϹÝÀûÀ¸·Î, b=17.62, c=243.12 °¡ ¸¹ÀÌ »ç¿ëµÈ´Ù°í ÇÑ´Ù.


*** Âü°í¹®Çå[References] ***

https://en.wikipedia.org/wiki/Dew_point#Calculating_the_dew_point
Tdp = c*(ln(RH/100)+b*T/(c+T)) / (b-ln(RH/100)+b*T/(c+T))
ÀÛ¼ºÀÚÀÇ ¼ö½Ä±×¸²ÀÌ ¾ø½À´Ï´Ù. No picture for this formula
º¯¼ö¸í Variable º¯¼ö°ª Value º¯ ¼ö ¼³ ¸í Description of the variable