Architecture
°ÇÃà Architecture


¿Ëº®(retaining wall)ÀÇ Àüµµ(over turning)¿¡ ´ëÇÑ ÀúÇ× ¸ð¸àÆ®

ÀÛ¼ºÀÚ Uploader : Åä¸ñ±â»ç ÀÛ¼ºÀÏ Upload Date: 2021-09-27º¯°æÀÏ Update Date: 2022-06-06Á¶È¸¼ö View : 498

±×¸²°ú °°Àº ´Ü¸éÀ» °¡Áø ¿Ëº®ÀÇ Àüµµ¿¡ ´ëÇÑ ÀúÇ× ¸ð¸àÆ®¸¦ ±¸ÇÑ´Ù.

ÄÜÅ©¸®Æ®ÀÇ ´ÜÀ§Áß·® : ¥ãc (kN/m^3)

»ï°¢Çü°ú »ç°¢ÇüÀ¸·Î ³ª´©¾î ÄÜÅ©¸®Æ®ÀÇ Áß·®À» ±¸ÇÑ´Ù.

¨ç »ï°¢Çü ºÎºÐ : W1 = ¥ãc*(1/2)*a*H

¨è »ç°¢Çü ºÎºÐ : W2 = ¥ãc*b*H

¨é »ç°¢Çü ºÎºÐ : W3 = ¥ãc*(a+b)*h

µû¶ó¼­, O Á¡À» ±âÁØÀ¸·Î ÀúÇ× ¸ð¸àÆ® Mr Àº ´ÙÀ½°ú °°´Ù.

Mr = a*(2/3)*W1 + (a+b/2)*W2 + ((a+b)/2)*W3

Mr = a*(2/3)*¥ãc*(1/2)*a*H + (a+b/2)*¥ãc*b*H + ((a+b)/2)*¥ãc*(a+b)*h

*** Âü°í¹®Çå[References] ***

Mr = a*(2/3)*¥ãc*(1/2)*a*H + (a+b/2)*¥ãc*b*H + ((a+b)/2)*¥ãc*(a+b)*h
ÀÛ¼ºÀÚÀÇ ¼ö½Ä±×¸²ÀÌ ¾ø½À´Ï´Ù. No picture for this formula
º¯¼ö¸í Variable º¯¼ö°ª Value º¯ ¼ö ¼³ ¸í Description of the variable


¡Ø ÀÌ »çÀÌÆ®´Â ±¤°í¼öÀÍÀ¸·Î ¿î¿µµË´Ï´Ù.

¡Ú ·Î±×ÀÎ ÈÄ ¼ö½ÄÀÛ¼º ¹× Áñ°Üã±â¿¡ Ãß°¡ÇÒ ¼ö ÀÖ½À´Ï´Ù.
¡Ú To make new formula or to add this formula in your bookmark, log on please.


ÄÚ¸àÆ®

´ñ±Û ÀÔ·Â