Architecture
°ÇÃà Architecture


°¨¼¼Áö(Stilling Basin) ±æÀÌ, Type-II

ÀÛ¼ºÀÚ Uploader : anyway ÀÛ¼ºÀÏ Upload Date: 2023-03-12º¯°æÀÏ Update Date: 2023-03-12Á¶È¸¼ö View : 167

Èĸ£µå ¼ö(Froude Number) F ¸¦ ÀÌ¿ëÇÏ¿© °¨¼¼Áö (Type-II) ±æÀÌ L À» ±¸ÇÑ´Ù.

±×¸²¿¡¼­ F ¿¡ µû¸¥ L/d2 °ªÀ» Àо L À» ±¸ÇÒ ¼ö ÀÖ´Ù.

d2 ´Â µµ¼ö ÈÄÀÇ ¼ö½ÉÀÌ´Ù.

Stillwaypro ¿¡¼­´Â ȸ±ÍºÐ¼®À» ÅëÇÏ¿© L/d2 ¸¦ F ÀÇ ÇÔ¼ö·Î ´ÙÀ½°ú °°ÀÌ Á¦½ÃÇß´Ù.

L/d2 = -0.0000987*F^4 + 0.005*F^3 - 0.0976*F^2 + 0.866*F + 1.41

µû¶ó¼­,

L = (-0.0000987*F^4 + 0.005*F^3 - 0.0976*F^2 + 0.866*F + 1.41)*d2

°¡ µÈ´Ù.

*** Âü°í¹®Çå[References] ***

Design of Small Dams, 1987.
Spillwaypro.
L = (-0.0000987*F^4 + 0.005*F^3 - 0.0976*F^2 + 0.866*F + 1.41)*d2
ÀÛ¼ºÀÚÀÇ ¼ö½Ä±×¸²ÀÌ ¾ø½À´Ï´Ù. No picture for this formula
º¯¼ö¸í Variable º¯¼ö°ª Value º¯ ¼ö ¼³ ¸í Description of the variable


¡Ø ÀÌ »çÀÌÆ®´Â ±¤°í¼öÀÍÀ¸·Î ¿î¿µµË´Ï´Ù.

¡Ú ·Î±×ÀÎ ÈÄ ¼ö½ÄÀÛ¼º ¹× Áñ°Üã±â¿¡ Ãß°¡ÇÒ ¼ö ÀÖ½À´Ï´Ù.
¡Ú To make new formula or to add this formula in your bookmark, log on please.


ÄÚ¸àÆ®

´ñ±Û ÀÔ·Â