Architecture
°ÇÃà Architecture


Flowrate of water used according to the power of the hydroelectric generator

ÀÛ¼ºÀÚ Uploader : aproduite ÀÛ¼ºÀÏ Upload Date: 2023-05-12º¯°æÀÏ Update Date: 2023-05-12Á¶È¸¼ö View : 84

Generator power (P) = turbine output (Pt) ¡¿ generator efficiency (Eg)

Turbine output (Pt) = g¡¿q¡¿H¡¿Et

here,
g : Gravity acceleration (9.8m/s^2)
q : Maximum flowrate of water used (m^3/s)
H : Effective head (m)
Et : Turbine efficiency

Therefore, the flowrate of water used according to the P (kW) of the generator can be calculated by the following formula.

q = P/(g ¡¿ H ¡¿ Et ¡¿ Eg)

*** Âü°í¹®Çå[References] ***

q = P/(g ¡¿ H ¡¿ Et ¡¿ Eg)
ÀÛ¼ºÀÚÀÇ ¼ö½Ä±×¸²ÀÌ ¾ø½À´Ï´Ù. No picture for this formula
º¯¼ö¸í Variable º¯¼ö°ª Value º¯ ¼ö ¼³ ¸í Description of the variable


¡Ø ÀÌ »çÀÌÆ®´Â ±¤°í¼öÀÍÀ¸·Î ¿î¿µµË´Ï´Ù.

¡Ú ·Î±×ÀÎ ÈÄ ¼ö½ÄÀÛ¼º ¹× Áñ°Üã±â¿¡ Ãß°¡ÇÒ ¼ö ÀÖ½À´Ï´Ù.
¡Ú To make new formula or to add this formula in your bookmark, log on please.


ÄÚ¸àÆ®

´ñ±Û ÀÔ·Â